This menu page is used to configure the Loudness Numeric instrument. This instrument is available after one of the loudness modes has been selected for the current audio group. It displays the numerical readout of the M, S, I and LRA measurements, the maximum values TPmax, Mmax, Smax, and the duration of the measurement (I-time) conforming to the selected recommendation, or to a customer specific setting. If needed, the numerical readouts of these individual loudness measurements can be activated or disabled individually. The values of current running measurements for I, LRA, TPmax, Mmax, Smax, and I-time values will be colored green, those of stopped measurements yellow. If values are exceeding the upper limits, they will be colored red.
Options: |
|
all active | M | S | I | LRA | TPmax | Mmax | Smax | I-time |
Default value: |
|
S, I, I-time |
Options: |
|
0 LU to 10 LU in steps of 0.1 LU |
Default value: |
|
EBU: +1.0 LU | ITU/ATSC/CALM/OP-59: +2.0 LU | ARIB: 0.0 LU | AGCOM: +0.5 LU |
Options: |
|
0 LU to 10 LU in steps of 0.1 LU |
Default value: |
|
EBU: +1.0 LU | ITU/ATSC/CALM/OP-59: +2.0 LU | ARIB: 0.0 LU | AGCOM: +0.5 LU |
Options: |
|
-4 dBTP to 0 dBTP in steps of 0.1 dBTP |
Default value: |
|
-1.0 dBTP |