Display Mode - Loudness Numeric Instrument (Loud. Num.)

  

 
 
General Description  

In display mode, the TouchMonitor shows the instruments and their layout defined in the currently loaded preset.

Touching the screen area of an instrument will put this instrument into focus. This is recognized by a colored frame instead of a grey one. The frame color conforms to the identifier set for the group the focused instrument belongs to.

The Control Bar positioned at the lower screen edge contains several keys. It is displayed permanently if the "Control Bar" option in the "General" section of the "System" menu is set to "permanent". Otherwise, it will be displayed temporarily after touching the screen.

The Control Bar has two sections. The left (upper) section shows the specific keys defined for the focused instrument. This makes it very fast to access a specific function of one of the instruments on screen – just touch the instrument and select the desired function.
The right (lower) section shows general keys.

  

Please note:
The specific keys that are displayed in the left (upper) Control Bar section can be defined individually for each instrument. To do this, touch the "Edit Instrument" key and select the "Configure Keys" option in the menu. The default value for each key can be set in the menu as well.

  

 back to top 
 


Instrument Description  

The Loudness Numeric instrument (Loud. Num.) is only available after one of the loudness modes or custom was selected for the audio group the instrument is in. According to selected standard or to the customer specific settings it displays the numerical readout of the running loudness measurements and maximum values.

M (Momentary):

  

Summed momentary loudness measurements of the individual channels using an integration time of 400 ms.

S (Shortterm):

  

Summed loudness measurement using an integration time of 3 s and a sliding window.

I (Integrated):

  

Overall program loudness between start and end points that are entered manually. Use the Start, Stop and Reset buttons to execute this measurement.

LRA:

  

Loudness Range

TPmax:

  

The highest measured True Peak value in dBFS

Mmax:

  

The highest measured Momentary value

Smax:

  

The highest measured Shortterm value

Itime:

  

Duration of the Integrated measurement

If needed, the numerical readouts of these individual loudness measurements can be activated or disabled individually. The values of current running measurements for I, LRA, TPmax, Mmax, Smax, and Itime values will be colored green, those of stopped measurements yellow. If values are exceeding the upper limits, they will be colored red.

  

 back to top 
 


Control Bar - left (upper) section: Loudness Numeric instrument functions  

With the Loudness Numeric instrument in focus, the left (upper) section of the Control Bar may contain any or all of the keys described below.

  

Please note:
Using the "Configure Keys" option in the Loudness Numeric Menu, any key available for the Loudness Numeric instrument may be removed from the Control Bar. Only keys set to "On" (default) in the Control Bar section of the "Loudness Numeric Key Settings" menu are available in normal display mode with the Loudness Numeric instrument in focus.

  

• Start
This key is used to start the loudness measurement. The values of running measurements are displayed in green, exceeding scale limits in red.

  

• Stop
This key is used to stop the loudness measurement. The current measured values are displayed in yellow.

  

• Reset Loudness
This key is used to reset the numerical loudness summing displays.

  

• Start + R (pulse)
This key is used to start the loudness measurement with a preciding reset. Use the "Stop" or "Pause" key to stop or halt the measurement.

  

• Start + R (envel)
This key is used to start the loudness measurement for as long as the key is pressed with a preciding reset. To stop the measurement just release the key.

  

Please note:
This functionality is only available through the GPI port. The on-screen key cannot emulate a latched condition.

  

• Pause
This key is used to halt the loudness measurement.

  

 back to top 
 


Control Bar - right (lower) section  

The right (lower) section of the Control Bar always contains the following four keys:

  

• Edit Instrument
This key is used to directly access the menu parameters of the focused instrument. Any edits in the menu are saved to the current preset using the "Save" key.

  

• Load Preset
This key is used to load one of the presets stored in the unit’s internal memory or on an USB storage medium connected to one of the USB ports.

  

• Menu
This key is used to enter the Main Menu. This is the starting point for global system configuration, licence handling and preset management.

  

• Help
This key is used to enter the onscreen help for normal display mode (this text). Depending on the focused instrument, the help page will also describe the individual keys of this instrument.

  

 back to top