Moving Coil (needle instruments)

  
  
  
Specifications (Extract of the data sheet)
  

Display Type: PPM (L/R), PPM (M/S), VU, Loudness, PPM + Loudness (L/R; M, S, or I), selectable
  
PPM:
   - Ch. arrangement: Dual, Dual + M/S horizontal, Dual + M/S vertical, Stereo horizontal, Stereo vertical
   - Scales:   BR IIa: 7. .1, BR IIa ext: 7. .1
      BR IIb: +12. .-12 dB, BR IIb ext: +12. .-12 dB
   - Integration time: Sample (digital only), 0.1 ms, 1 ms, 10 ms, 20 ms, 150 ms
   - Headroom Ref: available with digital sources only: -10 dB; adjustable from 0 to -20 dB in steps of 1 dB
   - S mode: only available, if M/S type is selected: M3, M6
   - Peak indicator: Off, Peak, True Peak, BR Peak
   - BR Peak Threshold: 6 dB,
      BR IIa: adjustable from 4 to 7 dB in steps of 1 dB
      BR IIb: adjustable from 0 to 12 dB in steps of 1 dB
  
VU:
   - Ch. arrangement: Stereo horizontal, Stereo vertical
   - Scale analog: VU (-20 to +3 dB)
   - Scale digital: VU Digital (-20 to + 3 dB)
   - Lead: 0 dB, adjustable from 0 to 12 dB in steps of 1 dB
   - Peak-Indikator: Off, Peak, True Peak
  
Loudness:
   - Ch. arrangement: Dual, Stereo horizontal, Stereo vertical
   - Scales: acc. to Loudness settings
   - Integration time: acc. to standard
   - Peak indicator: Off, no selectable option available
  
PPM + Loudness:
   - Ch. arrangement: Dual-PPM (as described above) with additional Loudness display (BBC) for M, S, or I (selectable) in one instrument
   - Scales:   PPM: see above
      Loudness: +9 to -9 LU fixed (mid of scale corresponds to Target Level)
  
Numerical display: switchable in all modes