Multichannel-PPM |
|
|
Specifications (Extract of the data sheet) |
|
General |
|
Input source: |
analog, digital, SDI and/or AoIP depending on selected audio interface (HW209nn) |
|
Surround Peakmeter: |
for 3.1, 5.0, 5.1, 7.1 formats |
Track layout: |
selectable for 5.1 Surround: |
|
|
|
SMPTE.TV: L, R, C, LF, LS, RS |
|
|
|
SMPTE.Film: L, LS, C, RS, R, LF |
|
|
|
DTS: L, R, LS, RS, C, LF |
|
|
|
L, C, R, LF, LS, RS |
|
|
|
Film: L, C, R, LS, RS, LF |
|
preset for 7.1 Cinema Surround: |
|
|
|
SMPTE (L, LC, C, RC, R, LS, RS, LFE) |
|
preset for 7.1 DD+ Surround: |
|
|
|
L, C, R, LS, RS, LSR, RSR, LFE |
|
Multichannel Peakmeter: |
2 to 8 single channels in one defined block (depending on the audio interface up to 4 blocks) |
|
2-channel Peakmeter: |
for different Stereo channel pairs |
|
Single-channel Peakmeter: |
for different Mono signals |
|
Display: |
|
up to 8 channels in one audio group (max. 32 channels depending on configuration) |
|
|
Peak level< |
|
|
Peak hold |
|
|
Numerical value of the display |
|
|
Digital Over |
|
Functions: |
|
Gain (+20 dB, +40 dB acc. to standard) |
|
|
Peak hold on/off |
|
|
Memory |
|
|
Reset |
|
Analog Peakmeter |
|
Analog scales: |
|
DIN5: +5 .. -50 dB |
|
|
DIN10: +10 .. -50 dB |
|
|
Nordic: +12 .. -42 dB |
|
|
BR IIa: 7 .. 1, BR IIa ext: 7..1 |
|
|
BR IIb: +12 .. -12 dB, BRIIb ext: +12..-12 dB |
|
|
Zoom10: +10 .. -10 |
|
|
Zoom1: +1 .. -1 |
|
|
SMPTE24: +24 .. -30 |
|
|
SMPTE20: +20 .. -40 |
|
|
NHK |
|
Integration time: |
acc. to standard or 20 ms, 10 ms, 1 ms, 0,1 ms additional 150 ms for British scales |
|
Peak hold indicator: |
1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off |
|
Digital Peakmeter |
|
Wort width: |
24 bit |
|
Digital scales: |
|
TP60: +3 .. -60 dB |
|
|
TP20: +3 .. -20 dB |
|
|
Dig60: 0 .. -60 dB |
|
|
Dig20: 0 .. -20 dB |
|
|
Dig0: +18 .. 0 dB |
|
|
Dig18: +18 .. -18 dB |
|
|
Dig40: +20 .. -40 dB |
|
|
ARD9: +9 .. -60 dB |
|
|
DIN5: +5 .. -50 dB |
|
|
DIN10: +10 .. -50 dB |
|
|
Nordic: +12 .. -42 dB |
|
|
BR IIa: 7 .. 1, BR IIa ext: 7..1 |
|
|
BR IIb: +12 .. -12 dB, BRIIb ext: +12..-12 dB |
|
|
Zoom10: +10 .. -10 |
|
|
Zoom1: +1 .. -1 |
|
Headroom/Headroom Ref: |
adjustable in the range from 0 to -20 dB in steps of 1 dB |
|
Operation field: |
adjustable in the range from 0 to -20 dB in steps of 1 dB |
|
Integration time (Attack): |
acc. to corresponding standard or selectable: Sample, 20 ms, 10 ms, 1 ms, 0.1 ms, additional 150 ms for British scales |
|
All Peakmeter |
|
Bargraph display: |
Solid, segment, classic (gas plasma display emulation) |
|
Gain: |
+20 dB, +40 dB, acc. to standard |
|
High-pass filter: |
Off, 5 Hz, 10 Hz, 20 Hz |
|
Peak hold indicator: |
1 s, 2 s, 4 s, 10 s, 20 s, 30 s, manual reset or off |
|
Over indicator hold time: |
1 s or manual |
|
Over indicator PPM |
- Threshold: |
Full Scale, Full Scale -1LSB, Full Scale -2LSB, -0.1 dBFS, -0.5 dBFS, -1 dBFS, -2 dBFS, -3 dBFS |
- Attack time: |
1 to 15 samples |
- Wort width: |
16 to 24 bit, selectable |
|
Over indicator True Peak |
- Threshold: |
adjustable |
|