Loud. Recal. (Loudness Recalculation) |
|
|
Specifications (Extract of the data sheet) |
Display : |
numerical display of |
|
|
current timecode |
|
|
start time < current timecode < stop time with recalculation |
|
Start: |
- Functions: |
Autostart after preset load, autostart with gate, autostart with gate and autoreset, manually via keys or GPI. With Timecode Reader licence (SW20008) activated additional control via
timecode resp. timecode with recalculation. |
- Level for gate: |
-70,0 LUFS/LKFS; adjustable from -85 to -10 LUFS/LKFS in steps of 0.5 LUFS/LKFS |
|
Stop: |
- Functions: |
manually via keys or GPI, autostop with gate, autostop with gate and time. The stop function is automatically set and fixed to timecode, if the start function has been set to a timecode option. |
- Level for gate: |
-70,0 LUFS/LKFS; adjustable from -85 to -10 LUFS/LKFS in steps of 0.5 LUFS/LKFS |
- Time for gate: |
1 s; adjustable from 1 to 15 s in steps of 1 s |
|