Loud. Recal. (Loudness Recalculation)

  
  
  
Specifications (Extract of the data sheet)
  

Display : numerical display of
      current timecode
      start time < current timecode < stop time with recalculation
  
Start:
   - Functions: Autostart after preset load, autostart with gate, autostart with gate and autoreset, manually via keys or GPI. With Timecode Reader licence (SW20008) activated additional control via timecode resp. timecode with recalculation.
   - Level for gate: -70,0 LUFS/LKFS; adjustable from -85 to -10 LUFS/LKFS in steps of 0.5 LUFS/LKFS
  
Stop:
   - Functions: manually via keys or GPI, autostop with gate, autostop with gate and time. The stop function is automatically set and fixed to timecode, if the start function has been set to a timecode option.
   - Level for gate: -70,0 LUFS/LKFS; adjustable from -85 to -10 LUFS/LKFS in steps of 0.5 LUFS/LKFS
   - Time for gate: 1 s; adjustable from 1 to 15 s in steps of 1 s