Archived: Panel-mount Peakmeters 40 x 190

Archival: Peakmeters in standard broadcasting cassette 40 x 190 mm

NOTE: The devices are no longer available!


These RTW peak program meters in standard broadcasting cassettes (40 x 190 mm) feature high precision, robust design and long-lived electronics that don’t need adjustment for demanding applications in studios, broadcasting, network control rooms, outside broadcasting units, analog and digital mastering. All units use reliable gas plasma displays (neon orange), guaranteeing excellent legibility even under poor lighting and outstanding precision thanks to the very high resolution (201 segments per channel).

The panel-mount peak program meters are available in five basic versions with different instrumentation and with customary standards (Digital, DIN, British, Nordic, ARD+9).

Features

      General

  • Panel-mount units in metal cassettes with standard dimensions: 40 x 190 mm, 107 mm depth
  • High-resolution, 201-segment gas plasma display, scale length 127 mm
  • Sandwich scale for horizontal or vertical installation
  • All models conform to the applicable standards (IRT 3/6, British, Nordic)

      Additional features of the analog peakmeters

  • Power supply 24 V, +/-15 V DC
  • Standard 32-pin DIN 41612/C connector
  • Transformer-balanced inputs (except 1113G: electronically balanced)
  • Input sensitivity +6 dBu (British +8 dBu)
  • Measurement range -50 dB to +5 dB (DIN versions)

      Additional features of the digital peakmeters

  • Power supply 22–30 V DC
  • Standard 64-pin DIN 41612/C connector  
  • Transformer-balanced AES/EBU input, input signals actively buffered
  • Digital scale -60 dB FS to 0 dB FS, also quasi-DIN or [ARD+9]
  • User-adjustable headroom markers
  • Sampling rates 27 kHz to 96 kHz
  • Overload display with adjustable sensitivity and attack time
  • Peak hold display

Models

1113G - no longer available -


DIN Standard

2-ch. peakmeter with electronically balanced analog inputs and 201 segments gas plasma displays

  • DIN scale (-50 to +5 dB, reference level for 0 dB reading: +6 dBu, headroom 0 to 5 dB, integration time 10 ms)

 

1115G - no longer available -


DIN Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • DIN scale (-50 to +5 dB, reference level for 0 dB reading: +6 dBu, headroom 0 to 5 dB, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain

1117G - no longer available -


DIN Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • DIN scale (-50 to +5 dB, reference level for 0 dB reading: +6 dBu, headroom 0 to 5 dB, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain
  • Fast Mode (1 ms)
  • Peak Hold

1119G - no longer available -


DIN Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • DIN scale (-50 to +5 dB, reference level for 0 dB reading: +6 dBu, headroom 0 to 5 dB, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter

1019GL - no longer available -


DIN Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • DIN scale (-50 to +5 dB, reference level for 0 dB reading: +6 dBu, headroom 0 to 5 dB, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter
  • Peak Hold
  • Loudness

1130G - no longer available -


BRITISH Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • British IIa scale ("1" to "7", -12 to +12 dB, reference level for "6" reading: +8 dBu, headroom "6" to "7", integration time 10 ms)
  • Peak Memory
  • 40 dB Gain

1134G - no longer available -


BRITISH Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • British IIa scale ("1" to "7", -12 to +12 dB, reference level for "6" reading: +8 dBu, headroom "6" to "7", integration time 10 ms)
  • Peak Memory
  • 40 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter

1034GL - no longer available -


BRITISH Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • British IIa scale ("1" to "7", -12 to +12 dB, reference level for "6" reading: +8 dBu, headroom "6" to "7", integration time 10 ms)
  • Peak Memory
  • 40 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter
  • Peak Hold
  • Loudness

1139G - no longer available -


NORDIC Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • Nordic N9 scale (-42 to +12 dB, reference level for +6 dB reading: +6 dBu, headroom +6 to +12 dB, integration time 5 ms)
  • Peak Memory
  • 40 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter

1039GL - no longer available -


NORDIC Standard

2-ch. peakmeter with transformer balanced analog inputs and 201 segments gas plasma displays

  • Nordic N9 scale (-42 to +12 dB, reference level for +6 dB reading: +6 dBu, headroom +6 to +12 dB, integration time 5 ms)
  • Peak Memory
  • 40 dB Gain
  • Fast Mode (1 ms)
  • Phase Meter
  • Peak Hold
  • Loudness

11520G - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • Digital scale (-60 to 0 dBFS, selectable headroom, default setting -9 dBFS, integration time Sample)
  • Peak Memory
  • 40 dB Gain

11520G-DIN - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • quasi-DIN scale (-50 to +5 dB, 0 dB mark at digital level of headroom setting, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain

11519G - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • Digital scale (-60 to 0 dBFS, selectable headroom, default setting -9 dBFS, integration time Sample)
  • Peak Memory
  • 40 dB Gain
  • Phase Meter

11519G-DIN - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • quasi-DIN scale (-50 to +5 dB, 0 dB mark at digital level of headroom setting, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain
  • Phase Meter

11529G - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • Digital scale (-60 to 0 dBFS, selectable headroom, default setting -9 dBFS, integration time Sample)
  • Peak Memory
  • 40 dB Gain
  • Phase Meter
  • Peak Hold
  • Loudness

11529G-DIN - no longer available -


DIGITAL Standard

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • quasi-DIN scale (-50 to +5 dB, 0 dB mark at digital level of headroom setting, integration time 10 ms)
  • Peak Memory
  • 20 dB Gain
  • Phase Meter
  • Peak Hold
  • Loudness

11528G - no longer available -


DIGITAL: Special Version for broadcast applications [ARD+9]

2-ch. peakmeter with transformer balanced digital AES/EBU input, digital output, sampling rates from 27 to 96 kHz and 201 segments gas plasma displays

  • Special Digital scale [ARD+9]:

    • Measuring range -60 to 0 dBFS
    • Scale range -60 to +9 dB with 0 dB mark at fixed headroom of  -9 dBFS
    • Double indication: peak level (0 ms) with either peak level (10 ms) or RTW loudness

  • Integration time Sample
  • Overload indicator
  • Peak Memory
  • 40 dB Gain
  • Phase Meter
  • Loudness

1170C - no longer available -


Analog Phase Meter

2 analog inputs, 2 analog outputs, input level -20 to +22 dBu, 21 segment LED display, three colors, scale -1 r to + 1 r

 

Downloads